Control Panels Vista 15p,20P,21ip
False alarm reducing features, security
enhancements and end user appeal make the economical VISTA-15 the industry’s
most sophisticated, versatile control. With both hardwire and wireless
expansion and features like Night Arming and Cancel Verification, the VISTA-15
can meet even the most demanding requirements.
Superior Flexibility
VISTA-15 has the installation flexibility
& expandability to be used in simple configurations, complex installs and
everything in between.
·
Six hardwired zones
· Expands to 32 total
zones (up to 26 wireless and/or 14 hardwired zones)
·
16 user codes
·
48 event log with
date/time stamp
·
Two-wire or four-wire
smoke detectors
·
Fast and easy E2
programming mode
Security & False Alarm Reducing
Enhancements
VISTA-15 has incorporated SIA false alarm
reducing requirements with the latest technology.
·
Exit delay reset
·
Alarm cancel
verification
·
Unvacated “Auto-Stay”
·
Cross zoning/alarm
verification
·
Short vs. open
detection & reporting
·
Telephone-line monitor
·
Arming level increase
Valuable End User System Features
VISTA-15 offers your customers a choice of
system features that add value to any install.
·
Easy-to-use single
button operation
• Arm Away • Arm Stay
• Arm Night • Page
·
Quick exit
·
Quick arm
·
X-10 control & 4
relays supported for home management
·
Enhanced paging
capabilities
·
24-hour monitoring
zone
·
Compatible keypad
family
Wide Selection of Easy to Use End User
Interface Devices
With superior wireless remote control, phone
operation and choice of keypads, VISTA-15 can be easily operated to fit your
customers needs.
·
Wireless remote
control
– 5804 - Four button, fully programmable key
– 5804BD - Four button, fully programmable key with status feedback for added
security
– 5827BD - Wireless keypad with status feedback
·
Phone Control
– 4285 - Turns any touch-tone phone into a voice response keypad
·
If you would like more information you can
contact us by one of the methods listed in the need an estimate located in the
Customer Care or simply click HERE
·
Vista 20p
The high capacity, feature-rich VISTA-20P lets
you deliver more value to your customers on each and every sale with up to 48
zones of protection, Internet uploading/downloading, graphic keypad support and
dual partitions. VISTA-20P gives you the ability to send alarm signals and
upload/download via an Internet Protocol (IP), improving the speed at which
information can be delivered to and from the control panel. In addition, the
VISTA-20P, used with an AlarmNet Internet or digital communicator can be
installed in premises without TELCO lines with no sacrifice in functionality.
The panel’s installation advantages, innovative end-user benefits and robust
system capacity make the value-priced VISTA-20P an ideal choice for higher end
installations.
Features
·
IP alarm reporting and
uploading/downloading capability for Internet and Intranet use via iGSMV,
7845i-ENT or GSMV
·
Supports four graphic
touchscreen keypads
·
Wireless keys can be
programmed without using zones
·
Eight on-board
hardwired zones standard (15 when Zone Doubling feature is used)
– 40 hardwire expansion zones
– 40 wireless expansion zones
·
Two low current
on-board trigger outputs
·
100 Event Log viewable
at system keypads with time/date stamp
·
48 system user codes
assignable to either partition
·
Expandable to 48 total
zones when used with hardwired and/or wireless expansion modules
·
Two independent
partitions plus a common partition
– Global Arming from any system keypad
– Go to function to view or operate one partition from the other
– Separate partition account numbers
·
16 output devices
– Relays (Model 4204 Relay Modules, or 4229 Expansion Module), and/or X-10®
devices (when used with a 4300 Transformer)
·
Four
installer-configurable zone types allows the installer to create custom zone
types by assigning all zone attributes
·
Supports four-wire and
up to 16 two-wire smokes
– Works with Sentrol CleanMe™ maintenance signal
·
Multiple actions on
output devices depending on system state
– Turns lights off when system arms
– Turns the same light on when system disarms
– Flashes same lights when system is in alarm
·
Built-in phone line
cut monitor with programmable delay and annunciation options
– Display on system keypads
– Trigger local sounders
– Trigger system bell
Security Dealer Features
·
Automatic System Load
Shed
– During extended AC power fail, the system battery will be disconnected to
prevent irreversible battery failure. Reduces service calls to replace
batteries.
·
Dynamic Signaling
– Reduces redundant reporting to the central station when multiple reporting
methods are used; i.e. digital dialer and AlarmNet radio
Valuable End-User Features
·
Viewable on system
keypads:
– Exit countdown
– Time and date display*
– Event log*
·
Auto keypad
backlighting on entry
·
Keyswitch arming
·
Programmable macro
buttons and single-button arming
·
Supports a variety of
wireless remote controls for single-button operation
·
User Scheduling
– Automatically activates X-10 and relays at programmed times
– Latchkey reports to pagers
– Auto arm/disarm
– “User access” time windows
·
Supports up to four
end-user numeric pagers
·
VIP Module allows
system control from any touchtone phone
·
Chime by zone
·
If you would like more information you can
contact us by one of the methods listed in the need an estimate located in the
Customer Care or simply click HERE
·
vista21ip
Honeywell’s high capacity, feature-rich
VISTA-21iP lets you deliver more value to your customers on each and every
sale. The VISTA-21iP provides up to 48 zones of protection, an on-board IP
connection, graphic keypad support and dual partitions. The VISTA-21iP gives
you the ability to send alarm signals and upload/download via an Internet
Protocol (IP), improving the speed at which information can be delivered to
and from the control panel. When used with an optional AlarmNet GSM that
snaps right on the board, the VISTA-21iP can be installed in premises without
TELCO lines – guaranteeing communication independent of any infrastructure.
The panel’s installation advantages, innovative end-user benefits and robust
system capacity make the value-priced VISTA-21iP an ideal choice for
higher-end installations.
Product Overview (Flash)
Features
·
Internet
alarm reporting and uploading/downloading capability via on-board AlarmNet
Internet Communicator
·
Supports
four graphic touchscreen keypads
·
Wireless
keys can be programmed without using zones
·
Eight
on-board hardwired zones standard (15 when Zone Doubling feature is used)
– 40 hardwired expansion zones
– 40 wireless expansion zones
·
Two
low current on-board trigger outputs
·
100
Event Log viewable at system keypads with time/date stamp
·
48
system user codes assignable to either partition
·
Expandable
to 48 total zones when used with hardwired and/or wireless expansion modules
·
Two
independent partitions plus a common partition
– Global arming from any system keypad
– Goto function to view or operate one partition from the other
– Separate partition account numbers
·
16
output devices
– Relays (Model 4204 Relay Modules, or 4229 Expansion Module), and/or X-10®
devices (when used with a 4300 Transformer)
·
Four
installer-configurable zone types allows the installer to create custom zone
types by assigning all zone attributes
·
Supports
four-wire, and up to 16 two-wire smokes
– Works with Sentrol CleanMe™ maintenance signal
·
Multiple
actions on output devices depending on system state
– Turns lights off when system arms
– Turns the same light on when system disarms
– Flashes same lights when system is in alarm
·
Built-in
phone line cut monitor with programmable delay and annunciation options
– Display on system keypads
– Trigger local sounders
– Trigger system bell
Security Dealer Features
·
Automatic
System Load Shed
– During extended AC power fail, the system battery will be disconnected to
prevent irreversible battery failure. Reduces service calls to replace
batteries.
·
Dynamic
Signaling
– Reduces redundant reporting to the central station when multiple reporting
methods are used; i.e. digital dialer and AlarmNet radio
Valuable End-User Features
·
Viewable
on system keypads:
– Exit countdown
– Time and date display*
– Event log*
·
Auto
keypad backlighting on entry
·
Keyswitch
arming
·
Programmable
macro buttons and single-button arming
·
Supports
a variety of wireless remote controls for single-button operation
·
User
Scheduling
– Automatically activates X-10 and relays at programmed times
– Latchkey reports to pagers
– Auto arm/disarm
– “User access” time windows
·
Supports
up to four end-user numeric pagers
·
VIP
Module allows system control from any touchtone phone
·
Chime
by zone
If you would like more information you can contact us
by one of the methods listed in the need an estimate located in the Customer
Care or simply click HERE
|
|